24 Hour Call Out Electricians
Guildford EICR Testing & Electrical Safety Certificates
Want an Electrical Installation Condition Report in a hurry? For a new tenancy, a property sale or following a fault, we inspect, test and report without keeping you waiting.
- Suitable for landlords, sellers and homeowners
- The whole installation inspected and tested
- A plain-English report of our findings
- Pricing agreed before work begins
When time is short
If you need an urgent EICR
An EICR is a complete check of a property's fixed wiring. These are the situations in which people tend to need one in a hurry.
Starting a tenancy
Before tenants move in, landlords in England must have a valid EICR, and a fresh one at least every five years from then on.
Buying or selling a home
Before contracts are exchanged, a report shows buyers and sellers exactly where the electrics stand.
Following a fault or fire
When something has gone wrong, a full test shows whether the remainder of the installation is safe to use.
Following a flood or leak
Water can harm wiring that is hidden from view. Testing confirms which circuits are safe to switch back on.
Insurance and licensing requirements
Insurers and licensing schemes frequently ask for a current report, particularly for rental properties and HMOs.
Out-of-date report
Has your last EICR run out? We can carry out the inspection promptly so you're covered once more.
The issue in detail
Understanding EICR testing
An Electrical Installation Condition Report is a thorough examination of a property's fixed wiring. Below is what we inspect, what we look out for and what follows if something fails.
What the report covers
Everything forming part of the building's electrical installation is included: the fuse board, wiring, sockets, switches, light fittings and any fixed equipment. Plug-in appliances aren't tested as part of it, as these fall under portable appliance testing. The purpose is to pick up anything damaged, worn, dangerous or short of current safety standards.
Each defect is logged on the report with a code. C1 means danger is present and calls for immediate action. C2 means potentially dangerous. C3 means an improvement is recommended. FI means further investigation is needed. A single C1, C2 or FI makes the report unsatisfactory.
The usual culprits
- Perished insulationAgeing cables lose their insulating qualities, which appears as low insulation resistance readings.
- No RCD protectionOlder installations often have no RCDs on the sockets and other circuits that now need them.
- Broken accessoriesCracked sockets, loose switches and damaged fittings with live parts exposed.
- Inadequate earthing and bondingEarthing and bonding to gas and water pipes that is missing or insufficient raises the risk of shock.
- Signs of overheatingScorch marks at terminals or inside the fuse board point to connections that have been running hot.
- Unsafe modificationsDIY additions, overloaded circuits and work that falls short of the regulations.
How we put it right
We begin the inspection by looking over the fuse board, accessories and visible wiring. The power is then switched off in stages as we test each circuit, checking earth conductor continuity, insulation resistance between conductors, polarity, earth fault loop impedance and RCD operation, and noting every result on the report.
Should the report come back unsatisfactory, we go through each defect in plain English and quote for the remedial work. Typical fixes are replacing damaged accessories, adding RCD protection, upgrading the fuse board, improving earthing and bonding, or swapping out perished cables. When the work is finished we re-test, so you end up with the paperwork you need.
On the visit
Inside an EICR visit
This is what you can expect when we carry out the inspection.
Visual check
We look over the fuse board, sockets, switches and visible wiring for damage and wear.
Circuit testing
Power is turned off in stages as each circuit is tested.
Written report
You receive a written report stating whether the installation is satisfactory, with anything needing attention listed.
Remedial work
If anything fails, we can quote for the repairs and re-test when they're complete.
Facing an electrical emergency now?
We reach you within 30 to 90 minutes, day or night.
Safety certificates
Electrical safety and EICR certificates in Guildford
People call an EICR by several names: an Electrical Installation Condition Report, an electrical safety certificate, a landlord electrical certificate, a periodic inspection or an electrical safety check. All of them mean the same thing, a full inspection and test of a property's fixed wiring.
Our work includes landlord EICRs for rented homes, holiday lets and HMOs, electrical safety checks for buyers and sellers, and periodic inspections for homeowners in Guildford, Godalming, Woking and the surrounding area. If you need one in a hurry, we can usually fit you in quickly.
Where your report flags problems, we can quote for the remedial work and re-test afterwards, so you end up with a satisfactory electrical safety certificate without needing to look for another electrician.
Common queries
Commonly asked questions
How long will an EICR take?
That depends on how big the property is and how many circuits it has. For an average home, expect a few hours.
Will the power go off?
Yes, during parts of the testing. We'll let you know when, and keep the time without power as short as we can.
What do the codes on the report mean?
C1 is danger present, C2 is potentially dangerous, C3 is improvement recommended and FI is further investigation needed. Any C1, C2 or FI means the report is unsatisfactory.
How frequently do I need one?
Rented homes need one at least every five years. For owner-occupied homes, the usual guidance is every ten years, or when you move house.
More help